![]() Preheat the printer nozzle with M104 S230.Set the Thermal model warning value very low with M310 W0.1.Enable temperature and fan auto report with M155 S1 C3.Home printer G28 W and move it to the middle of the bed G1 X125 Y105 Z1.Continue only if your last few prints have been printed without TM warnings or errors.So if you have a good idea how to "suck" heat out of the REVO nozzle with tool please let us know. Holding the E3Dv6 heat block with some pillars/wrench that makes good contact also is working but difficult on the round REVO that even has a silicone sock. ![]() On REVO we could cause it by using an air can, compressed air.On E3Dv6 it can be easily done by using a strong fan or strong hairdryer (on cold) blowing air at the nozzle.To simulate an issue it is needed to remove heat from the system that is unusual: Goal is to find the narrowest TM Warning settings to detect issues as fast as possible while preventing false positives. This task is for users who have provided the log files and have a well calibrated REVO MK3/S printer. Blow compressed air on nozzle / block (without / with silicone ring) Hold nozzle (without silicone ring) during preheat with a big wrenchĢ9. Set warning value back to default M310 W1.2Ģ8. The default warning is set to 1.2 and error to 1.74Ģ6. Lower the TM warning values in 0.1 steps with M310 W1.1, M310 W1.0. Print something to verify that no THERMAL ANOMALY messages are shown, ideally with serial loggingĢ5.The TM cal should be ignored as it already passed.Printer should restart during connection and show the Wizard.Start new terminal session to log the wizard.Send D3 Ax0f5f X01 to set Wizard active.Send D3 Ax0ca6 C1 to check calibration v2 status.Send M310 A F0 to run Thermal model cal.Send M155 S1 C3 to auto report temps and fans.Send G1 X125 Y105 Z1 to move the hotend to the middle of the bed.Send `G28 W" to home all without mesh bed level.Wait until the printer is cold □ before you continue.Send M310 S0 to temporary disable TM for PID cal.Perform a Factory reset by pressing the knob during boot/start up (you don't have to but makes things easier to compare). ![]() Here the steps our internal test team was following. Octopi Blacklist is in Settings -> Features-> Terminal Auto Uppercase Blacklist add here the D3 gcode. Please use Putty, OctoPrint (with D3 as exception to be UPPER CASED), or other serial terminal scripts: Please don't use Pronterface/printrun as it UPPER-CASES D3 commands which are case sensitive. It would be great if you could run the tests below and give us some feedback. ![]() We have a new firmware release FW 3.12.2 which includes some PTC / REVO improvements see ❤️ □ □Īs the issue got very long I would like to continue collecting data log files here. First we want to thank everyone here for providing feedback, testing and reporting log files in #3636. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |